50 Ω SMB Specifications
Electrical |
||
Impedance |
50 Ω |
|
Frequency Range |
0-4 GHz with low reflection; usable to 10.0 GHz |
|
Voltage Rating for RG-188/U Cable |
335 volts at sea level and 85 volts at 70,000 feet |
|
Dielectric Withstanding Voltage |
RG-196: 750 VRMS; RG-188: 1,000 VRMS |
|
VSWR |
Straight connector, RG-196/U: 1.30 + .04 f (GHz) |
|
Contact Resistance |
Center contact: 6.0 mΩ initial, 8.0 after environmental; |
|
Insulation Resistance |
1,000 MΩ minimum |
|
Insertion Loss |
Straight connector: 0.30 dB @ 1.5 GHz |
|
RF Leakage |
-55 dB minimum @ 2-3 GHz |
|
Mechanical |
||
Mating |
Snap-on coupling per MIL-STD-348 |
|
Braid/Jacket Cable Affixment |
Hex crimp |
|
Center Conductor Cable Affixment |
Solder |
|
Contact Captivation |
All types unless noted otherwise |
|
Cable Retention |
Equal to breaking strength of cable employed |
|
Engagement Forces |
Engagement: 14 lbs maximum |
|
Connector Durability |
500 mating cycles minimum |
|
Material |
||
Center Contact |
Female: beryllium copper, gold-plated |
|
Outer Contact Plating |
Nickel or gold plating as indicated |
|
Body |
Brass per QQB-626, or zinc per ASTM B86-71 |
|
Body Plating |
Nickel or gold plating as indicated |
|
Insulator |
TFE |
|
Crimp Ferrule |
Annealed copper alloy |
|
Environmental |
||
Temperature Range |
- 65°C to +165°C |
|
Thermal Shock |
MIL-STD-202 method 107, test condition B (except high temperatures @ 200°C |
|
Shock |
MIL-STD-202 method 202, method 13, snap-on, test condition B; 75 G's @ 6 milliseconds ½ sine |
|
Vibration |
MIL-STD-202 method 204, snap-on, test condition B; (15 G's) |
|
Corrosion |
MIL-STD-202 method 101, test condition B. 5% salt solution |
Note: These characteristics are typical but may not apply to all connectors.